back2root:ibm-pc-ms-dos:hardware:8272-pd765 [2023/02/23 22:28] – [Key to Abbreviations] frater | back2root:ibm-pc-ms-dos:hardware:8272-pd765 [2023/02/23 22:30] (Version actuelle) – [Key to Abbreviations] frater | ||
---|---|---|---|
Ligne 387: | Ligne 387: | ||
<WRAP round box> | <WRAP round box> | ||
* PS/2 systems use the 8272A diskette controller which is software and port compatible with the NEC µPD765 | * PS/2 systems use the 8272A diskette controller which is software and port compatible with the NEC µPD765 | ||
- | * accessed through ports 3F0h-3F7h; NEC µPD765 is accessed through ports 3F2h, 3F4h and 3F5h; the 8272A uses ports 3F0h, 3F1h, 3F2h, 3F4h, 3F5h and 3F7h | + | * accessed through ports 3F0h-3F7h;\\ NEC µPD765 is accessed through ports 3F2h, 3F4h and 3F5h;\\ the 8272A uses ports 3F0h, 3F1h, 3F2h, 3F4h, 3F5h and 3F7h |
* data, command and status registers are all accessed through port 3F5h a register stack with one address presented to the bus | * data, command and status registers are all accessed through port 3F5h a register stack with one address presented to the bus | ||
* bit 7 of BIOS Data Area byte 40:3E can be polled to determine if a disk operation has completed; this bit is set by the interrupt handler when the operation has completed; it should be reset before continuing on with the next FDC operation | * bit 7 of BIOS Data Area byte 40:3E can be polled to determine if a disk operation has completed; this bit is set by the interrupt handler when the operation has completed; it should be reset before continuing on with the next FDC operation |